GE Xiao-qin, GENG Xue-bing. Determination of 7 pyrethroids residues in aquatic product by gas chromatography[J]. Journal of fisheries of china, 2009, 33(1): 132-138.
Citation: GE Xiao-qin, GENG Xue-bing. Determination of 7 pyrethroids residues in aquatic product by gas chromatography[J]. Journal of fisheries of china, 2009, 33(1): 132-138.

Determination of 7 pyrethroids residues in aquatic product by gas chromatography

  • Gas chromatography with electron capture detection method was developed for the determination of 7 pyrethroids residues in aquatic products. Pyrethroids were extracted with cyclohexane and ethylacetate(1:1,V/V)and lipids were removed with petroleum ether. Cleanup was performed on a LC-Florisil column. The working curves for the pyrethroids were linear (r>0.992) in the range of 1 to 100 μg/L. When spiked with 5, 10 and 20 μg/kg of pyrethroids, the average recoveries were 70.0%~114.8% and the intra-day RSD(n=5) were 1.2%~9.8% and the inter-day RSD(n=3) were 3.8%~11.2%. The detection limit as estimated by 2 times signal to noise method for bifenthrin, fenpropathrin, lambdacyhalothrin, permethrin was 1 μg/kg and for permethrin, fenvalerate, deltamethrin was 2 μg/kg respectively.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return